OSHA Regulated Area Sign Requirements: Silica, Asbestos and Lead Legends

Some OSHA chemical standards do not just say "post a sign." They spell out the exact words. For these, a generic danger sign is not enough.

Respirable crystalline silica: 1910.1053

Post signs at all entrances to regulated areas, where exposure is or could be over the permissible exposure limit, bearing this legend:

Danger
Respirable crystalline silica
May cause cancer
Causes damage to lungs
Wear respiratory protection in this area
Authorized personnel only

Asbestos: 1910.1001

Warning signs go at each regulated area and at all approaches, so people can read them and take protective steps before entering:

Danger
Asbestos
May cause cancer
Causes damage to lungs
Authorized personnel only

Where respirators and protective clothing are required, the sign must also say so. Signs with the old legend ("Cancer and lung disease hazard") were only allowed until June 1, 2016.

Lead: 1910.1025

Post in each work area where exposure is above the permissible exposure limit:

Danger
Lead work area
May damage fertility or the unborn child
Causes damage to the central nervous system
Do not eat, drink or smoke in this area

Use the wording as written. These standards say no statement may appear on or near the required sign that contradicts or detracts from it. OSHA has said changing the required asbestos legend to a different ANSI-style message is a violation. Buy signs that carry the exact legend.

Construction work has its own standards: 1926.1101 for asbestos and 1926.62 for lead. The construction silica rule, 1926.1153, uses a written exposure control plan instead of regulated area signs.

Signs that meet this rule

All are checked. Uncheck any you already have, then add the rest in one click.

  • Respirable Crystalline Silica Regulated Area (1910.1053 legend)
  • Asbestos, May Cause Cancer (1910.1001 legend)
  • Lead Work Area, May Damage Fertility (1910.1025 legend)

Reference: 29 CFR 1910.1053(j)(2); 1910.1001(j)(4); 1910.1025(m)(2); OSHA interpretation letter of Oct. 13, 2015.

This page is a plain-language summary to help you plan signs. It is not legal advice. Check the current standard and your local code or inspector for your exact situation.

Related: OSHA 1910.1200 HazCom · Respiratory protection guide · All sign requirements

Every CGAP sign is 8x12 Heavy-Gauge Aluminum, rust-resistant, UV-resistant and pre-drilled, made in the USA. Need different wording? Design your own sign. Buying for a facility or agency? Build a PO quote.