OSHA Exit Sign Requirements (1910.37): Exit, Not an Exit and Exit Route Signs

29 CFR 1910.37 covers how exit routes are kept and marked in general industry. The sign rules are short and specific.

What 1910.37(b) requires

  • Mark every exit. Each exit must be clearly visible and marked by a sign reading "Exit."
  • Keep the line of sight open. The line of sight to an exit sign must be clearly visible at all times, and exit route doors must be free of decorations or signs that hide them.
  • Show the way. Where the direction to the nearest exit is not immediately apparent, post signs along the exit access showing the way.
  • Mark doors that are not exits. Any doorway or passage that could be mistaken for an exit must be marked "Not an Exit" or a similar designation, or be marked with its actual use, such as "Closet."
  • Light it. Each exit sign must be illuminated to at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. Self-luminous or electroluminescent signs with a surface value of at least 0.06 footlamberts are allowed.
  • Size the letters. The word "Exit" must be in plainly legible letters at least six inches high, with principal strokes at least three-fourths of an inch wide.

OSHA also lets an employer comply by following NFPA 101, the Life Safety Code, instead (1910.35). Many local fire codes follow NFPA 101 or the International Fire Code, so check with your fire marshal.

What our signs cover: the lit EXIT sign over the door should be a listed illuminated or photoluminescent unit. Our aluminum signs handle the rest of the job: Not an Exit doors, keep exit clear reminders, assembly points and AED locations. OSHA has also said the ISO running-man exit symbol may be shown next to the required word "Exit."

Keep the route clear

1910.37(a) requires exit routes to be free and unobstructed, with no materials or equipment placed in them, even temporarily. A keep clear sign at doors that collect pallets and carts is one of the cheapest fixes for a common citation.

Signs that meet this rule

All are checked. Uncheck any you already have, then add the rest in one click.

  • Not an Exit
  • Fire Exit, Keep Clear
  • Emergency Assembly Point
  • AED Location

Reference: 29 CFR 1910.35 and 1910.37; OSHA interpretation letter of May 25, 2022 (ISO exit symbol).

This page is a plain-language summary to help you plan signs. It is not legal advice. Check the current standard and your local code or inspector for your exact situation.

Related: Fire extinguishers (1910.157, NFPA 10) · Blocked egress guide · All sign requirements

Every CGAP sign is 8x12 Heavy-Gauge Aluminum, rust-resistant, UV-resistant and pre-drilled, made in the USA. Need different wording? Design your own sign. Buying for a facility or agency? Build a PO quote.